Get a Pentest and security assessment of your IT network.

2021-current

CVE-2020-15791 – A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. r

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.

 

Source: https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-15791

Reference (s):

  • https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf
  • URL: https://cert-portal.siemens.com/productcert/pdf/ssa-381684.pdf